"EVERY LONG JOURNEY STARTS WITH SMALL STEP"

BIO TECHNICS INDIA has traveled a long way to reach its present position as a household word in the world of Science and Scientists. The inspiration behind this
journey was derived form a team

     
 
Product Range --------
 
 
 
BACTERIOLOGICAL INCUBATOR (BOTTOM HEATER) BTI-25
 

  • Bacteriological Incubators Are Sturdy Double Walled Units.
  • Inner Chamber Made Of M.S. / S.S. And Outer Made Of Mild Steel With Powder Coating.
  • Gap Between The Wall Fitted With Glass Wool Insulation To Avoid Heat Loses.
  • Heating Elements Are Made Of High Grade Chrome Plated Nicrome Wire.
  • Temp. Is Controlled By Thermostat.
  • Temp. Range 5°C Above Ambient To 60°C And Accuracy. +2°C (With Digital Accuracy ±0.5°C)
  • Air Ventilations Is Provided On The Top Of The Unit To Remove The Hot Gases / Furnes.
  • In Lab Type Incubators Heaters Are Placed In The Bottom Side Of The Unit.
  • All The Control Switches And Pilot Lamps Are Fitted On The Front Panel
  • Trays Should Be Supplied With G.I. Wire Mesh.
 
Standard Sizes Available :

Size in Inches (In Cms.)
(H X W X D)
12" X 12" X 12"
(30 x 30 x 30 Cm.)
14" X 14" X 14"
(35 x 35 x 35 Cm.)
18" X 18" X 18"
(45 x 45 x 45 Cm.)
18" X 18" X 24"
(45 x 45 x 60 Cm.)
24" X 24" X 24"
(60 x 60 x 60 Cm.)
18" X 24" X 36"
(45 x 60 x 90 Cm.)
24" X 24" X 36"
(60 x 60 x 90 Cm.)
 
Optional Accessories :
 
• Air Circulation Fan For Uniform Temperature.
• Digital Temp. Controller Cum indicator in lieu of thermostat with an accuracy of + 0.5°C.
• S.S. Trays
 
 

BACTERIOLOGICAL INCUBATOR ( MEMMERT TYPE )BTI-26

 

  • Bactriological Incubators Are Sturdy Double Walled Units.
  • Inner Chamber Made Of S.S. And Outer Made Of Mild Steel  With Powder Coating.
  • Gap Between The wall Fitted With Glass Wool Insulation To Avoid Heat Loses.
  • Heating Elements Are Made Of High Grade Chrome Plated Nicrome Wire.
  • Temp. Is Controlled By Thermostat.
  • Temp. Range 5°C Above Ambient To 60°C And Accuracy. +2°C (With digital accuracy ±0.5°C)
  • Air Ventilations Are Placed On Top Of Both Side To Remove Hot Gases / fumes.
  • In Memmert Type Unit Heaters Placed At The Right And Left Side Of The Inner Chamber.
  • All The Control Switches And Pilot Lamp Are Fitted On The Front Pannel.
  • Trays Should Be Supplied With G.I. Wire Mesh
 
Optional Accessories :
 
• Air Circulation Fan for Uniform Temperature.
• Digital Temp. Controller cum indicator in lieu of thermostat with an  accuracy of + 1 C
• S.S. Trays
• Out side chamber made of Stainless Steel.
 
Standard Sizes Available :

Size in Inches (In Cms.)
(H X W X D)
12" X 12" X 12"
(30 x 30 x 30 Cm.)
14" X 14" X 14"
(35 x 35 x 35 Cm.)
18" X 18" X 18"
(45 x 45 x 45 Cm.)
18" X 18" X 24"
(45 x 45 x 60 Cm.)
24" X 24" X 24"
(60 x 60 x 60 Cm.)
18" X 24" X 36"
(45 x 60 x 90 Cm.)
24" X 24" X 36"
(60 x 60 x 90 Cm.)
 
BACTERIOLOGICAL INCUBATOR (MEMMERT TYPE) BTI-04
 


  • Bactriological Incubators Are Sturdy Double Walled Units.
  • Inner Chamber Made Of S.S. And Outer Made Of Mild Steel WithPowder Coating.
  • Gap Between The Wall Fitted With Glass Wool Insulation To Avoid Heat Loses.
  • Heating Elements Are Made Of High Grade Chrome Plated Nicrome Wire.
  • Temp.  Is Controlled By Termostat.
  • Temp. Range 5c Above To 60° And Accuracy. +2°C.
  • Air Ventilation Are Placed  On Top Of Both Sides To Remove Hot Gases / Fumes.
  • In Memmert Type Unit Heaters Placed At The Right And Left Side Of the Inner Chamber
  • All The Control Switches And Pilot Lamps Are Fitted On The Front Panel.
  • Trays Should Be Suppliued With G.i. Wire Mesh.
Standard Sizes Available :

Size in Inches (In Cms.)
(H X W X D)
12" X 12" X 12"
(35 x 35 x 35 Cm.)
14" X 14" X 14"
(35 x 35 x 35 Cm.)
18" X 18" X 18"
(45 x 45 x 45 Cm.)
18" X 18" X 24"
(45 x 45 x 60 Cm.)
24" X 24" X 24"
(60 x 60 x 60 Cm.)
18" X 24" X 36"
(45 x 60 x 90 Cm.)
24" X 24" X 36"
(60 x 60 x 90 Cm.)
 
Optional Accessories :
 
• Air Circulation Fan For Uniform Temperature.
• Digital Temp. Controller Cum indicator in lieu of thermostat with an accuracy of + 0.5°C.
• S.S. Trays
 
BACTERIOLOGICAL INCUBATOR (BOTTOM HEATER)
 

  • Incubators Are Sturdy Double Walled Units.
  • Inner Chamber Made Of S.S. And Outer Made Of Mild Steel With Powder Coating.
  • Gap Between The Wall Fitted With Glass Wool Insulation To Avoid  Heat Loses.
  • Heating Elements Are Made Of High Grade Chrome Plated Nicrome Wire.
  • Temp. Is Controlled By Thermostat.
  • Temp. Range 5°C Above Ambient To 60° And Accuracy. +2°C
  • Air Ventilations Is Provided On TheTop Of the Unit To Remove The Hot Gases / Fumes.
  • In Lab Typoe Incubators Heaters Are Placed In The Bottom Side Of The Unit.
  • All The Control Switches & Pilot Lamps Are Fitted On The Front Pannel.
  • Trays Should be Supplied With G.I. Wire Mesh.
 
Standard Sizes Available :

Size in Inches (In Cms.)
(H X W X D)
12" X 12" X 12"
(35 x 35 x 35 Cm.)
14" X 14" X 14"
(35 x 35 x 35 Cm.)
18" X 18" X 18"
(45 x 45 x 45 Cm.)
18" X 18" X 24"
(45 x 45 x 60 Cm.)
24" X 24" X 24"
(60 x 60 x 60 Cm.)
18" X 24" X 36"
(45 x 60 x 90 Cm.)
24" X 24" X 36"
(60 x 60 x 90 Cm.)
 
Optional Accessories :
 
• Air Circulation Fan For Uniform Temperature.
• Digital Temp. Controller Cum indicator in lieu of thermostat with an accuracy of + 0.5°C.
• S.S. Trays
• Out Side Chamber Made Of stainless Steel.
 
 
 
     
 
 
 
  Quick Contacts ... 3, Vaishali Mansion, Bldg.No.9,   Sorabji Santuk Lane, Dhobi Talao, Mumbai - 400002, Maharashtra, India
Tel. No :- (022) 65948121 / 64515653 Fax No.:- (022) 22058121

Website : www.biotechlabequipments.com, www.laboratoryequipmentsindia.net
* Scientific Instrument.
| Environmental Test Chamber | Cryostat Baths/ Recirculators | Horizontal Laminar Air Flow |
| Stability Cooling Chambers | Constant Temperature Water Bath | Laminar Air Flow | Filter Holder |
* Oven
| Vertical Autoclave | Muffle Furnace | Memmert Type Hot Air Oven | Round Vaccum Oven |